Quantcast
Channel: Ethernet Switching topics
Viewing all articles
Browse latest Browse all 2326

EX2300 Validating Config for firmware downgrade

$
0
0

After validating the install I receive this error:

 

Hardware Database regeneration succeeded
Validating against /config/juniper.conf.gz
Chassis control process: <xnm:error xmlns="http://xml.juniper.net/xnm/1.1/xnm" xmlns:xnm="http://xml.juniper.net/xnm/1.1/xnm">
Chassis control process: <source-daemon>chassisd</source-daemon>
Chassis control process: <edit-path>[edit interfaces]</edit-path>
Chassis control process: <statement>xe-0/1/0</statement>
Chassis control process: <message>INTERFACES_TYPE_UNIDIR: Error in parsing interface name</message>
Chassis control process: </xnm:error>
mgd: error: configuration check-out failed
Validation failed
Validating against /config/rescue.conf.gz
Chassis control process: <xnm:error xmlns="http://xml.juniper.net/xnm/1.1/xnm" xmlns:xnm="http://xml.juniper.net/xnm/1.1/xnm">
Chassis control process: <source-daemon>chassisd</source-daemon>
Chassis control process: <edit-path>[edit interfaces]</edit-path>
Chassis control process: <statement>xe-0/1/0</statement>
Chassis control process: <message>INTERFACES_TYPE_UNIDIR: Error in parsing interface name</message>
Chassis control process: </xnm:error>
mgd: error: configuration check-out failed
Validation failed
/usr/libexec/ui/validate-config.sh: op_fix_config: not found
ERROR: Current configuration not compatible with junos-arm-32-15.1X53-D56.tgz

 

 

The switch is running 15.1x3-D57.3, I need to change this to stay standard and because there is a Mac address issue with D57.3. The switch is remote and the interface in question is the Uplink port so I am afraid to do a no-validate.

The strange part is I have other EX2300 switches at the same location with the same config that had no problem with the downgrade. Any help would be great.


Viewing all articles
Browse latest Browse all 2326

Trending Articles