Hello Team,
I need help with confirming whether I have power supply failure. If so, I have to open an RMA with TAC.
User@EX9204> show chassis power PEM 0: State: Online AC input: OK (1 feed expected, 1 feed connected) Capacity: 2050 W (maximum 2050 W) DC output: 57 W (zone 0, 1 A at 57 V, 2% of capacity) PEM 1: State: Online AC input: OK (1 feed expected, 1 feed connected) Capacity: 2050 W (maximum 2050 W) DC output: 174 W (zone 0, 3 A at 58 V, 8% of capacity) PEM 2: State: Present AC input: Out of range (1 feed expected, 1 feed connected) Capacity: 2050 W (maximum 2050 W) DC output: 0 W (zone 0, 0 A at 0 V, 0% of capacity) PEM 3: State: Online AC input: OK (1 feed expected, 1 feed connected) Capacity: 2050 W (maximum 2050 W) DC output: 57 W (zone 0, 1 A at 57 V, 2% of capacity)
PEM2 is showing 'Present' but not Online. I have verified the physical power connection. Can anyone please confirm if this a PS failure?