Hello,
I have virtual chassis with 2 EX2300 switches. Today, I saw red led on one of the switches, but I couldn't find the reason of that.
How can I find the issue?
{master:0} root> show chassis led LED status for: FPC 0 ----------------------------------- LEDs status: Alarm LED : Red System LED: Green Master LED: Green Interface LED(SPD/DPX/ADM/POE) ------------------------------------- ge-0/0/0 Green ge-0/0/1 Green ge-0/0/2 Green ge-0/0/3 Off ge-0/0/4 Off ge-0/0/5 Off ge-0/0/6 Off ge-0/0/7 Off ge-0/0/8 Off ge-0/0/9 Off ge-0/0/10 Off ge-0/0/11 Off ge-0/0/12 Off ge-0/0/13 Off ge-0/0/14 Off ge-0/0/15 Off ge-0/0/16 Off ge-0/0/17 Off ge-0/0/18 Off ge-0/0/19 Off ge-0/0/20 Off ge-0/0/21 Off ge-0/0/22 Off ge-0/0/23 Off LED status for: FPC 1 ----------------------------------- LEDs status: Alarm LED : Yellow Beacon LED: Beacon ON System LED: Green Master LED: Green Blinking Phone Home LED: Green Interface LED(SPD/DPX/ADM/POE) ------------------------------------- ge-1/0/0 Green ge-1/0/1 Green ge-1/0/2 Green ge-1/0/3 Off ge-1/0/4 Off ge-1/0/5 Off ge-1/0/6 Off ge-1/0/7 Off ge-1/0/8 Off ge-1/0/9 Off ge-1/0/10 Green ge-1/0/11 Off ge-1/0/12 Off ge-1/0/13 Off ge-1/0/14 Off ge-1/0/15 Off ge-1/0/16 Off ge-1/0/17 Off ge-1/0/18 Off ge-1/0/19 Off ge-1/0/20 Off ge-1/0/21 Off ge-1/0/22 Off ge-1/0/23 Off root> show chassis alarms 2 alarms currently active Alarm time Class Description 1970-01-01 01:11:35 UTC Major Host 1 me0 : Ethernet Link Down 2000-01-02 01:02:23 UTC Major Host 0 me0 : Ethernet Link Down root> show system alarms 2 alarms currently active Alarm time Class Description 1970-01-01 01:11:35 UTC Major Host 1 me0 : Ethernet Link Down 2000-01-02 01:02:23 UTC Major Host 0 me0 : Ethernet Link Down root> show chassis fpc pic-status Slot 0 Online EX2300-24T PIC 0 Online 24x10/100/1000 Base-T PIC 1 Online 4x10G SFP/SFP+ Slot 1 Online EX2300-24T PIC 0 Online 24x10/100/1000 Base-T PIC 1 Online 4x10G SFP/SFP+ root> show chassis environment Class Item Status Measurement Power FPC 0 Power Supply 0 OK FPC 1 Power Supply 0 OK Temp FPC 0 CPU Sensor OK 37 degrees C / 98 degrees F FPC 0 PSU Sensor OK 29 degrees C / 84 degrees F FPC 1 CPU Sensor OK 37 degrees C / 98 degrees F FPC 1 PSU Sensor OK 28 degrees C / 82 degrees F Fans FPC 0 Fan Tray 0 OK Spinning at normal speed FPC 1 Fan Tray 0 OK Spinning at normal speed root> show virtual-chassis status Virtual Chassis ID: a374.14cf.38cb Virtual Chassis Mode: Enabled Mstr Mixed Route Neighbor List Member ID Status Serial No Model prio Role Mode Mode ID Interface 0 (FPC 0) Prsnt JZ0219300138 ex2300-24t 255 Master* N VC 1 vcp-255/1/0 1 (FPC 1) Prsnt JZ0219300194 ex2300-24t 255 Backup N VC 0 vcp-255/1/0 root> show chassis environment routing-engine Routing Engine 0 status: State Online Master Temperature 37 degrees C / 98 degrees F Routing Engine 1 status: State Online Standby Temperature 37 degrees C / 98 degrees F root> show chassis power-budget-statistics fpc 0: ------------------------------------------------------------------------- PSU 0 (JPSU-65W-AC-AFO ) : 65 W Online Power redundancy configuration : N+0 Total power supplied by all online PSUs : 65 W Base power reserved : 55 W fpc 1: ------------------------------------------------------------------------- PSU 0 (JPSU-65W-AC-AFO ) : 65 W Online Power redundancy configuration : N+0 Total power supplied by all online PSUs : 65 W Base power reserved : 55 W root> show chassis temperature-thresholds Fan speed Yellow alarm Red alarm Fire Shutdown (degrees C) (degrees C) (degrees C) (degrees C) Item Normal High Normal Bad fan Normal Bad fan Normal FPC 0 CPU Sensor 45 52 63 63 71 71 76 FPC 0 PSU Sensor 37 42 57 57 65 65 71 FPC 1 CPU Sensor 45 61 63 63 71 71 76 FPC 1 PSU Sensor 37 55 57 57 65 65 71