Loop / flood in network after moving from EX to QFX

$
0
0

Hello,

We have the following topology:

CORE3 = EX4550-32T, 12.3R6.6

CORE3-New = QFX5100, 18.1R3-S7.1

CORE1 = EX4550-32F, 12.3R6.6


CORE3 config:

set forwarding-options analyzer VOIP input ingress interface xe-1/0/24.0
set forwarding-options analyzer VOIP input ingress interface xe-0/0/24.0
set forwarding-options analyzer VOIP input ingress interface xe-1/1/2.0 <--- UCS-B, P.25
set forwarding-options analyzer VOIP input ingress interface xe-0/1/2.0 <--- UCS-A, P.25
set forwarding-options analyzer VOIP input egress interface xe-1/0/24.0
set forwarding-options analyzer VOIP input egress interface xe-0/0/24.0
set forwarding-options analyzer VOIP input egress interface xe-1/1/2.0 <--- UCS-B, P.25
set forwarding-options analyzer VOIP input egress interface xe-0/1/2.0 <--- UCS-A, P.25
set forwarding-options analyzer VOIP output interface xe-0/0/27.0 <--- Recording Server (Output Mirror)

Above topology works on CORE3.

When we moved this topology and cables to a new switch "CORE3-New" , network got flooded, loss of pings, freezing of some switches, intermittent connectivity.

 

We then deactivated the analyzer on CORE3-New:

deactivate forwarding-options analyzer VOIP

but still the same behavior.


The solution *seems* to be configuring no-mac-learning on the mirror ports on the CORE3-New, we haven't tried that yet.

Currently we had to rollback and move the mirror ports to the old switch CORE3 and everything works again.

What is the difference between CORE3 and CORE3-New that might cause this behavior?

The configuration is the same, no-mac-learning is not configured on CORE3 and still everything works.


Any ideas?

 

 