hi
For troubleshooting perspective, which information in diagnostic optics is a key/standout between 2 interfaces below?
show interfaces diagnostics optics xe-1/0/18 Physical interface: xe-1/0/18 Laser bias current : 41.878 mA Laser output power : 0.6590 mW / -1.81 dBm Module temperature : 47 degrees C / 117 degrees F Module voltage : 3.2800 V Receiver signal average optical power : 0.0000 mW / - Inf dBm Laser bias current high alarm : Off Laser bias current low alarm : Off Laser bias current high warning : Off Laser bias current low warning : Off Laser output power high alarm : Off Laser output power low alarm : Off Laser output power high warning : Off Laser output power low warning : Off Module temperature high alarm : Off Module temperature low alarm : Off Module temperature high warning : Off Module temperature low warning : Off Module voltage high alarm : Off Module voltage low alarm : Off Module voltage high warning : Off Module voltage low warning : Off Laser rx power high alarm : Off Laser rx power low alarm : On Laser rx power high warning : Off Laser rx power low warning : On Laser bias current high alarm threshold : 70.000 mA Laser bias current low alarm threshold : 1.000 mA Laser bias current high warning threshold : 68.000 mA Laser bias current low warning threshold : 2.000 mA Laser output power high alarm threshold : 2.2380 mW / 3.50 dBm Laser output power low alarm threshold : 0.0600 mW / -12.22 dBm Laser output power high warning threshold : 1.1220 mW / 0.50 dBm Laser output power low warning threshold : 0.1510 mW / -8.21 dBm Module temperature high alarm threshold : 75 degrees C / 167 degrees F Module temperature low alarm threshold : -5 degrees C / 23 degrees F Module temperature high warning threshold : 70 degrees C / 158 degrees F Module temperature low warning threshold : 0 degrees C / 32 degrees F Module voltage high alarm threshold : 3.630 V Module voltage low alarm threshold : 2.970 V Module voltage high warning threshold : 3.465 V Module voltage low warning threshold : 3.135 V Laser rx power high alarm threshold : 2.2387 mW / 3.50 dBm Laser rx power low alarm threshold : 0.0145 mW / -18.39 dBm Laser rx power high warning threshold : 1.1220 mW / 0.50 dBm Laser rx power low warning threshold : 0.0363 mW / -14.40 dBm> show interfaces diagnostics optics xe-0/0/10 Physical interface: xe-0/0/10 Laser bias current : 42.444 mA Laser output power : 0.6320 mW / -1.99 dBm Module temperature : 49 degrees C / 121 degrees F Module voltage : 3.2600 V Receiver signal average optical power : 0.3278 mW / -4.84 dBm Laser bias current high alarm : Off Laser bias current low alarm : Off Laser bias current high warning : Off Laser bias current low warning : Off Laser output power high alarm : Off Laser output power low alarm : Off Laser output power high warning : Off Laser output power low warning : Off Module temperature high alarm : Off Module temperature low alarm : Off Module temperature high warning : Off Module temperature low warning : Off Module voltage high alarm : Off Module voltage low alarm : Off Module voltage high warning : Off Module voltage low warning : Off Laser rx power high alarm : Off Laser rx power low alarm : Off Laser rx power high warning : Off Laser rx power low warning : Off Laser bias current high alarm threshold : 85.000 mA Laser bias current low alarm threshold : 15.000 mA Laser bias current high warning threshold : 80.000 mA Laser bias current low warning threshold : 20.000 mA Laser output power high alarm threshold : 1.5840 mW / 2.00 dBm Laser output power low alarm threshold : 0.1580 mW / -8.01 dBm Laser output power high warning threshold : 1.2580 mW / 1.00 dBm Laser output power low warning threshold : 0.1990 mW / -7.01 dBm Module temperature high alarm threshold : 88 degrees C / 190 degrees F Module temperature low alarm threshold : -13 degrees C / 9 degrees F Module temperature high warning threshold : 85 degrees C / 185 degrees F Module temperature low warning threshold : -8 degrees C / 18 degrees F Module voltage high alarm threshold : 3.700 V Module voltage low alarm threshold : 2.900 V Module voltage high warning threshold : 3.600 V Module voltage low warning threshold : 3.000 V Laser rx power high alarm threshold : 1.7783 mW / 2.50 dBm Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm Laser rx power high warning threshold : 1.5849 mW / 2.00 dBm Laser rx power low warning threshold : 0.0158 mW / -18.01 dBm> show interfaces terse xe-0/0/10 Interface Admin Link Proto Local Remote xe-0/0/10 up up xe-0/0/10.0 up up eth-switch> show interfaces terse xe-1/0/18 Interface Admin Link Proto Local Remote xe-1/0/18 up down xe-1/0/18.0 up down inet