EX4200, PoE not working on all ports, how to set Voltage 24V instead 51.6V

$
0
0

hi all, I have issue when powerd up EX4200, poe is configured on all ports but seems that opeational status is off, this is config: 

 

set poe interface all
set poe interface all telemetries
set poe interface ge-0/0/0 disable
set poe interface ge-0/0/1 disable
set poe interface ge-0/0/2 disable
set poe interface ge-0/0/10 disable
set poe interface ge-0/0/11 disable

output of show commands:

 

# run show poe interface
Interface    Admin       Oper    Max        Priority       Power          Class
             status      status  power                     consumption
 ge-0/0/0    Disabled    Disabled 0.0W      Low            0.0W           not-applicable
 ge-0/0/1    Disabled    Disabled 0.0W      Low            0.0W           not-applicable
 ge-0/0/2    Disabled    Disabled 0.0W      Low            0.0W           not-applicable
 ge-0/0/3    Enabled     OFF     15.4W      Low            0.0W           not-applicable
 ge-0/0/4    Enabled     OFF     15.4W      Low            0.0W           not-applicable
 ge-0/0/5    Enabled     OFF     15.4W      Low            0.0W           not-applicable
 ge-0/0/6    Enabled     OFF     15.4W      Low            0.0W           not-applicable
 ge-0/0/7    Enabled     OFF     15.4W      Low            0.0W           not-applicable
 ge-0/0/8    Enabled     OFF     15.4W      Low            0.0W           not-applicable
 ge-0/0/9    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/10    Disabled    Disabled 0.0W      Low            0.0W           not-applicable
ge-0/0/11    Disabled    Disabled 0.0W      Low            0.0W           not-applicable
ge-0/0/12    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/13    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/14    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/15    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/16    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/17    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/18    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/19    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/20    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/21    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/22    Enabled     OFF     15.4W      Low            0.0W           not-applicable
ge-0/0/23    Enabled     OFF     15.4W      Low            0.0W           not-applicable

# run show poe controller
Controller  Maximum   Power         Guard    Management   Status        Lldp
index       power     consumption   band                                Priority
   0**      410.00W   0.00W           0W     Static       AF_MODE       Disabled

# run show poe telemetries
Interface  Sl No    Timestamp                Power    Voltage
 ge-0/0/4     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
 ge-0/0/5     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
 ge-0/0/6     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
 ge-0/0/7     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
 ge-0/0/8     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
 ge-0/0/9     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/12     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/13     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/14     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/15     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/16     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/17     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/18     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/19     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/20     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/21     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/22     1     03-13-2014 10:06:05 UTC  0.0W     51.6V
ge-0/0/23     1     03-13-2014 10:06:05 UTC  0.0W     51.6V

any idesa why operational status is off? hoiw can I convert port to supply 24V instead 51.6V? 51.6V might be to high for APs