Quantcast
Channel: Ethernet Switching topics
Viewing all 2326 articles
Browse latest View live

Port mirror of AE interfaces to a single port

$
0
0

Is it possible to mirror an AE interface that has child interfaces on different VC members to a single port on the following VCs:

  • EX4300 with two members: AE has 2 child interfaces (ge) - one on each member, to a single ge interface
  • EX4550 (x3), EX4200 (x2) mixed VC: AE has 2 child interfaces (xe) - on 2 of the EX4550, to a single xe interface

Of course I understand that the bandwidth of the AE interface could not exceed the bandwith of the analyser port for all traffic to be mirrored.


QFX3500-48s4q-acrb stuck in virtual chassis/linecard config

$
0
0

I would like to reset some QFX3500's that my company just got in back to fresh out of box factory config, however they seem to be stuck in a Virtual-chassis setup. I have even tried doing a fresh clean install from the loader prompt with the --format, and these units still seem to be stuck in the virtual chassis config. 

 

When I try doing the command "show chassis hardware detail" I get the following output.

 

root@P6893-C:LC:0% cli
root@P6893-C> show chassis hardware detail
error: the chassis-control subsystem is not running

root@P6893-C>

 

I have tried the "restart chassis-control" command. The units just come back stating that they could not be started.

 

I have tried doing a zeroize and going into config and doing a "load factory-default" when I do this command I get the following output.

 

root@P6893-C# load factory-default
warning: activating factory configuration
[edit]
'protocols'
warning: statement has no contents; ignored

[edit]
root@P6893-C#

 

for the life of me I just can't get these units to reset to factory defaults. 

What am I missing here?

Virtual Chassis technology in EX 4200

$
0
0

Hi everybody,

 

I hope you are doing fine, have a few questions:

 

1) Let say we have Virtual chasis with Sw1,SW2,SW3 with following roles:

SW1 is master

SW2 is back up RE

Sw3 is line card

 

Can Sw1 and SW2  forward tproduction traffic though they have assumed Master and back up RE role?  Most likely they can as it is very similar to VDX fabric technology in Brocade, just want to be sure as I have never configured EX switch in Virtual chasis .

 

Thanks and have a nice day!!

 

 

EX4300 most simple DHCP relay config?

$
0
0

Hi all,

We have couple EX4300 switches in VC configuration with ELS software version 14.1X53-D35.3.

They are used as a distribution switches and I'm trying to simplify current DHCP relay configuration.

I'm coming from Cisco world where you would only need to define ip helper-address under vlan interface to make DHCP relay configuration work.

With our current confguration everything is working but Junos is creating this subscriber database or binding database, whatever is right term.

And it also creates these Access-internal routes to routing table for each individual DHCP binding.

I would like to get rid of this behavior and make setup as simple as possible, like in Cisco.


forward-snooped-clients configured-interfaces;
overrides {
    allow-snooped-clients;
}
server-group {
    windowsservers-group {
        10.10.2.1;
        10.10.2.3;
    }
}
group office-pc {
    active-server-group windowsservers-group;
    interface irb.20;
}
group office-voip {
    active-server-group windowsservers-group;
    interface irb.21;
}

 

When installing EX switches we discovered that we needed these options so that lease renewing would work:

forward-snooped-clients configured-interfaces;
overrides {
    allow-snooped-clients;

 

And this had to be configured same way to our core switches where our DHCP servers are hosted. Core switches are also EX4300 with just different port configuration.

 

So, question is: What configuratio would stop Junos creating DHCP binding database and work just like Cisco does? So that unicast DHCP renew requests would go thru to server also.

/var partition usage on backup routing engine

$
0
0

Hello,

 

I have virtual chassis with two members:

 

Member ID  Status   Serial No    Model          prio  Role      Mode  Mode ID  Interface
0 (FPC 0)  Prsnt    xxxx ex4200-48t     129   Master*      N  VC   1  vcp-0    1  vcp-1      
1 (FPC 1)  Prsnt    xxxx ex4200-24t     129   Backup       N  VC   0  vcp-0    0  vcp-1   

 

 

I can not understand how to clean up /var partition, already did all from KB, but still have alarm.

Any suggestion?

 

admin@hostname> show chassis alarms 
1 alarms currently active
Alarm time               Class  Description
2010-01-10 22:22:07 EET  Minor  Host 1 /var partition usage is high

{master:0}
admin@hostname> request session member 1 

--- JUNOS 15.1R5.5 built 2016-11-25 16:39:56 UTC
warning: This chassis is operating in a non-master role as part of a virtual-chassis (VC) system.
warning: Use of interactive commands should be limited to debugging and VC Port operations.
warning: Full CLI access is provided by the Virtual Chassis Master (VC-M) chassis.
warning: The VC-M can be identified through the show virtual-chassis status command executed at this console.
warning: Please logout and log into the VC-M to use CLI.
{backup:1}

admin@hostname> start shell user root 
Password:
root@hostname:BK:1% df -h | grep var
/dev/da0s3e           123M    101M     12M    90%    /var <<<<<<<<
/dev/da0s3d           369M     17M    323M     5%    /var/tmp
/dev/md10             118M     19M     89M    18%    /var/rundb
root@sw-01:BK:1% pwd
/var root@hostname:BK:1% du -chs * | sort -rn 240K mfs 210K etc 138K run 112K jail 102K db 100K etcroot 41M total <<<<<<<< 19M rundb 17M tmp 14K spool 12K home 10K jails 6.0K at 4.2M log 4.0K transfer 4.0K sw 4.0K root 4.0K cron 4.0K crash 4.0K BSD.var.dist 2.0K yp 2.0K validate 2.0K rwho 2.0K preserve 2.0K named 2.0K msgs 2.0K mail 2.0K logical-systems 2.0K heimdal 2.0K empty 2.0K chroot 2.0K bin 2.0K backups 2.0K account

Thanks.

Qinq issue on mx104

$
0
0
Hi
I have customer that connected to switch
The switch qinq the customer vlan and send it to another switch that does also qinq and send it to the mx
The mx gets 3 vlans and needs to pop the 2 qinq vlans and attached the inner customer vlan to service internet
Is it possible?
I know that mx has vlan-tags with 1 outer and 1 inner
I need another inner vlan (customer vlan)
Also the interface configured under bridge domain
With routing interface irb

Dynamic installation Scenario for Virtual chasis mode

$
0
0

Hi everybody

 

Let say we have three EX 4200 switches: SW1, SW2,SW3,  we want to use " Dynamic Installation method" to configure them in a chasis mode.

We cable VCP ports in daaisy chained ring toplogy. We set up SW1 and SW2 priority as 255, while SW3 has a default priority of 128.

We power SW1 first then SW2 and finally SW3. They assume following roles:

SW1--Elected master

SW2--Back up RE

SW3--Line card

 

Let say we power down SW1, Sw2 assume  master and SW3 BACK UP RE role  now, next we power on SW1. What role SW1 ,SW2 and SW3 assume ?

 

MASTER ELECTION CRITERIA:

The algorithm proceeds from the top condition downward until the stated condition is satisfied:

  1. Choose the member with the highest user-configured mastership priority (255 is the highest possible value). A switch with a mastership priority of 0 will always stay in the linecard role.
  2. Choose the member that was master the last time the Virtual Chassis configuration booted.
  3. Choose the member that has been included in the Virtual Chassis configuration for the longest period of time. (For this to be a deciding factor, there has to be a minimum time lapse of 1 minute between the power-ons of the individual interconnected member switches.)
  4. Choose the member with the lowest MAC address.

 

 This is my hunch based on the above:

 

 When SW1 powers up and join the Chasis, SW3 will assume LINE CARD ROLE because it has the lowest priority of 128.

SW1 and SW2 have the same priority of 255 so 2nd criteria is used i.e who has the more time in the chasis, since SW1 just joins Chasis therefore SW2 remains Master and SW1 assumes BACK UP RE role.

 

Am I correct?

 

Thanks and have a nice weekend!!

 

 

 

Master RE , Back UP RE and Synchronization in Virtual chasis mode

$
0
0

Hi everybody,

 

 

1)Let say we have two EX4200 switches as master RE and back up RE in a virtual chasis mode, we make some configuration changes on master and simly commit it ( we do not use commit synchronize option), will the change still be propagated to back up RE? Is there any minimum interval or it happens right away as we make configuration changes to Master RE?

 

2)  Is it required all CONFIGURATION CHANGES be entered via MASTER RE i.e we can not go to a member switch and try to make configuration changes there ?  

 

 

Thanks and have a nice weekend!!

 

 


Configuring Uplink Port as VCP port for Virtual chasis and member ID

$
0
0

Hi everybody.

 

Let say we have two switches SW1,SW2 which do not have dediacted VCP port, we therefore decided to use UPLINK port as VPC port.

 

 

 

Both switches have factory default config.  Before we can connect them via VCP ports we must configure uplink port as VCP port.

 

We start with SW1:

SW1:

SW1> request virtual-chassis vc-port set pic-slot 1 

Above I did not specify any member id as we do not have one( remember this SW has factory defaults). So what value is assumed above?

 

SW2:

SW2>request virtual-chassis vc-port set pic-slot 1 

Above I did not specify any member id as we do not have one( remember this SW has factory defaults). So what value is assumed above?

 

Thanks and have a nice weekend!!

 

 

 

 

 

 

 

Does QFX5100 support VC by default?

$
0
0

Hi All,

 

 

As i'm undertstand QFX5100 need additional license if we want make VCF. But may i know how about normal VC. Is it QFX support it without license?

 

Thanks and appreciate anyone feedback

Problems with QFX10008

$
0
0

  A while ago we discovered that qfx10k is dropping transit frames with triple vlan tags. After long investigation with JTAC, A-JTAC, DEV Team, etc... they confirmed the problem but they are refusing to accept it as a bug. Moreover, The DEV team has confirmed that this is expected behavior, i.e. if  there is a triple tagged packet incoming to the switch(which is definitely a valid ethernet frame), the packet shall be dropped and not allow to pass through. As a result we have completely unusable switch with no chance to get it fixed.
Does anyone has experience how to deal in such situation? Any suggestions (except the court) are  appreciated

 

 

Thanks in advance

Best Regards

Michael Varyan

Redundant Trunk Group on EX and J series and LACP with Cisco router

$
0
0

Hi,
We are going to improve our current network by adding additional switch, router and firewall in order to eliminate single point of failure. Below is the network topology (also as attached), but I am not quite sure on the design especially on the redundant trunk group between routers and switches. Appreciate if you guys could give some comments on it. Secondly, does J-Series router support LACP? Our internet router is using Cisco 2960 and will connect to 2xJ6350 routers using LACP.

 

HA1.jpg

 

 

Tail-dropped packets on 30Gb AE while only ~8Gbps at max

$
0
0

Hi all,

 

I see lots of output drops on a 30g AE (consisting of three 10g interfaces). It's a 2 member EX4550 VC:

Model: ex4550-32f
Junos: 15.1R5.5

 

AE detail stats:

  Output errors:
    Carrier transitions: 44, Errors: 0, Drops: 127061556, MTU errors: 0, Resource errors: 0

Queue counters:       Queued packets  Transmitted packets      Dropped packets
  0                                0        8786218535053            126988388
  1                                0                    0                    0
  5                                0                    0                    0
  7                                0          29847977601                73168

 

Thing is, at max the interface is doing 'only' ~ 8Gbps. This is only at night. During the day (like now) it's only doing approx. 2G in and 2G out. And even than I got ~ 254 drops within a minute.

 

I understand tail-dropped means they're dropped because the buffer is full. But I really can't figure out why. At least looking at the bandwith, there's enough room.

 

One thing I just noticed, while checking when it appeared to have started: ~ 2016-12-29 01:36:04

That night, we replaced this stack with a new one which was installed with 15.1R5.5; (we did this to reduce downtime, as it's a core stack)

Also, from that moment on there's a huge increase of outbound traffic.. that concerns me ..

 

So one could think it's caused by the JunOS version?

 

Any insights would be appreciated! Smiley Happy

 

[edit: added images]

Setting up a new Virtual Chassis on EX3300

$
0
0

Hi,

 

I am looking into turning an EX3300 switch into a Virtual Chassis with 2 additional switches, making it 3 switches all together.

 

I've found many articles online explaining how to do this however I cannot find whether it requires downtime on the switch that currently exists? 

 

Can someone advise whether when configuring the active switch into a Virtual Chassis master, does this require downtime? 

 

I know adding additional switches to an existing VC does not require downtime, but not sure if when setting up a new VC.

 

Thank you,

Vishal

EX9208 R14 migration from VCP to VRRP and upgrade to R16

$
0
0

So in the PR for R16 it shows that juniper stops support on VC.  I am needing to move from R14.X to R16.X so that I can finally have LRm optical support for my client that has a surplus of LRMs.  We were looking into EVPN to migrate too but with all the case studys and burn in surrounding the new 10ks and the issues they are having we are going to hold off on going EVPN right away so we are looking at doing VRRP.  I dont see any documents on this migration.  


vme.0 up/down on new QFX5100 VC pair

$
0
0

I'm installing a new set of QFX5100s and am having difficulty with the vme management interface. I have two QFX5100s in a VC pair, and have C0 (em0) on each QFX5100 connected to our management network. Very minimal config on the QFXs, and we're at least initially not doing any layer-3 on them.

 

admin@dcas01a-ts1dc> show interfaces terse vme     
Interface               Admin Link Proto    Local                 Remote
vme                     up    down
vme.0                   up    down inet     10.38.4.87/24    

{master:0}
admin@dcas01a-ts1dc> show interfaces terse em0  
Interface               Admin Link Proto    Local                 Remote
em0                     up    up
em0.0                   up    up   

{master:0}

How many IRB interface suppoed on EX switch?

$
0
0

Hi ,

Does there have any document description for how many IRB interface supported on EX switch ?

Like:

Cisco Nexus 3K suppoed 1450 SVI

Extreme X670 suppoed 2000 SVI

 

Thanks for your answer .

EX4200 MACs relearned from other UP ports

$
0
0

Hello,

 

I have a little issue related to the MAC learning by a standalone switch. My setup is very simple - two end stations connected to one switch, MAC dynamically learned without any issues, pings are ok. Once I connected a new switch to some free ports on switch under question, no trunks yet, no STP either the MACs start bouncing in the table - learning of my PCs MAC is constantly changing . I mean I learn my macs from other UP ports those that will be used for trunking bust still access ports (default config). I dont observe that behaviour on cisco 3750.

 

Simple bridging within one ex4200 became impossible as soon as I turn up other ports. I'm using default config at the moment. RSTP temporarly disabled/deleted though. It seems I experience MAC flooding-relearning within the box L2 table. Ping now is intermittent. If more ports connected the hosts then will not be able to reach each other. 

 

Please advise what is missing, I think not much as I wanted this switch to perform basic L2 forwarding between local access ports.

I use Juno 12.3R5.7

 

 

Weird behaviour ex4600 and 10Gig sfp+ ports

$
0
0

Hi!

I have expirienced with a weird behaviour our EX4600 switch. I add sfp+ module at port and see that this port becomes up without any cables. What is a reason?

All leds on port are green

 

sfp - 10GBASE SR MM JDSU PLRXPL-SC-S43-J1 850 nm

 

1> show interfaces xe-1/0/23
Physical interface: xe-1/0/23, Enabled, Physical link is Up
Interface index: 795, SNMP ifIndex: 690
Description: Rezerv-SAPHANA
Link-level type: Ethernet, MTU: 1514, MRU: 0, Speed: 10Gbps, BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled,
Source filtering: Disabled, Flow control: Disabled, Media type: Fiber
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x4000
Link flags : None
CoS queues : 12 supported, 12 maximum usable queues
Current address: f4:a7:39:8d:e3:1a, Hardware address: f4:a7:39:8d:e3:1a
Last flapped : 2017-07-21 17:12:37 GMT-3 (00:02:47 ago)
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Active alarms : None
Active defects : None
Interface transmit statistics: Disabled

Logical interface xe-1/0/23.16386 (Index 591) (SNMP ifIndex 691)
Flags: Up 0x4004000 Encapsulation: ENET2
Input packets : 0
Output packets: 47

 

> show interfaces diagnostics optics xe-1/0/23
Physical interface: xe-1/0/23
Laser bias current : 5.688 mA
Laser output power : 0.5910 mW / -2.28 dBm
Module temperature : 48 degrees C / 118 degrees F
Module voltage : 3.3230 V
Receiver signal average optical power : 0.0055 mW / -22.60 dBm
Laser bias current high alarm : Off

EX4200 in Virtual Chassis lost

$
0
0

Our Configuration had 3 EX 4200 48P  switches in stack during a recent power failure the entire stack was rest and all the configuation was lost. We were able to restore the master with the backup configuration but the remaining 2 switches are stuck on loading junos. We can console into the switches and both of them are labeled as linecard 0 one was configured as backup and other was configured as line card with no split detection enabled. and virtual chassis preprovisioned. We tried to factory reset the switch so as to reconfigure it to be added to the stack but that does not work either.Tried to commit a config but keep getting error message

error: could not open /var/etc/pam.conf+: Operation not permitted

error: commit failed: foreign file propagation failed during preprocessing

 When i ran the  snapshot command  there is no output

{linecard:0}

root> show system snapshot media internal

 

{linecard:0}

root>

 

Are the switches Dead? We dont have any JTAC support on these switches. We are going to try booting the device via USB to see if that helps us to fix the issue. 

 

 

 

Viewing all 2326 articles
Browse latest View live