XE down since I'm not sending light?

$
0
0

I have a link that went down for what appears to be my fault? When I run the diag, it shows I'm not sending light? Why would that be? Any ideas?

 

FWIW, if I set the int to disable, commit and enable, commit, it comes up for 1 second and then goes down again. I've never seen this scenario before. Thanks for any troubleshooting tips!

 

Juniper MX 104 running 15.1R6.7

 

me@rtr# run show interfaces diagnostics optics xe-2/0/0
Physical interface: xe-2/0/0
Laser bias current : 0.000 mA
Laser output power : 0.0000 mW / - Inf dBm
Module temperature : 48 degrees C / 119 degrees F
Module voltage : 3.2670 V
Receiver signal average optical power : 0.7713 mW / -1.13 dBm
Laser bias current high alarm : Off
Laser bias current low alarm : On
Laser bias current high warning : Off
Laser bias current low warning : On
Laser output power high alarm : Off
Laser output power low alarm : On
Laser output power high warning : Off
Laser output power low warning : On
Module temperature high alarm : Off
Module temperature low alarm : Off
Module temperature high warning : Off
Module temperature low warning : Off
Module voltage high alarm : Off
Module voltage low alarm : Off
Module voltage high warning : Off
Module voltage low warning : Off
Laser rx power high alarm : Off
Laser rx power low alarm : Off
Laser rx power high warning : Off
Laser rx power low warning : Off
Laser bias current high alarm threshold : 85.000 mA
Laser bias current low alarm threshold : 15.000 mA
Laser bias current high warning threshold : 80.000 mA
Laser bias current low warning threshold : 20.000 mA
Laser output power high alarm threshold : 1.5840 mW / 2.00 dBm
Laser output power low alarm threshold : 0.1580 mW / -8.01 dBm
Laser output power high warning threshold : 1.2580 mW / 1.00 dBm
Laser output power low warning threshold : 0.1990 mW / -7.01 dBm
Module temperature high alarm threshold : 88 degrees C / 190 degrees F
Module temperature low alarm threshold : -13 degrees C / 9 degrees F
Module temperature high warning threshold : 85 degrees C / 185 degrees F
Module temperature low warning threshold : -8 degrees C / 18 degrees F
Module voltage high alarm threshold : 3.700 V
Module voltage low alarm threshold : 2.900 V
Module voltage high warning threshold : 3.600 V
Module voltage low warning threshold : 3.000 V
Laser rx power high alarm threshold : 1.7783 mW / 2.50 dBm
Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm
Laser rx power high warning threshold : 1.5849 mW / 2.00 dBm
Laser rx power low warning threshold : 0.0158 mW / -18.01 dBm

 

me@rtr# run show interfaces xe-2/0/0
Physical interface: xe-2/0/0, Enabled, Physical link is Down
Interface index: 173, SNMP ifIndex: 512
Link-level type: Ethernet, MTU: 1514, MRU: 1522, LAN-PHY mode, Speed: 10Gbps, BPDU Error: None, MAC-REWRITE Error: None, Loopback: None, Source filtering: Disabled, Flow control: Enabled
Pad to minimum frame size: Disabled
Device flags : Present Running Down
Interface flags: Hardware-Down SNMP-Traps Internal: 0x0
Link flags : None
CoS queues : 8 supported, 8 maximum usable queues
Current address: f4:**:**:**:**:**, Hardware address: f4:**:**:**:**:**
Last flapped : 2019-07-27 01:26:52 UTC (00:00:03 ago)
Input rate : 15656 bps (31 pps)
Output rate : 0 bps (0 pps)
Active alarms : LINK
Active defects : LINK
PCS statistics Seconds
Bit errors 0
Errored blocks 2
Interface transmit statistics: Disabled

 

 