Hello,
I am having concern about virtual-chassis setup on my qfx5110. Refering to below topology, when the vcp port down, both qfx become "Master". Is this default behavior when "no-split-detection" is configured?
{master:0} root@QFX-1> show virtual-chassis vc-port localre: -------------------------------------------------------------------------- Interface Type Trunk Status Speed Neighbor or ID (mbps) ID Interface PIC / Port 0/47 Configured -1 Down 10000
{master:0} root@QFX-1> show virtual-chassis status Preprovisioned Virtual Chassis Virtual Chassis ID: 1234.1234.1234 Virtual Chassis Mode: Enabled Mstr Mixed Route Neighbor List Member ID Status Serial No Model prio Role Mode Mode ID Interface 0 (FPC 0) Prsnt WS12341234 qfx5110-48s-4c 129 Master* N VC 1 (FPC 1) NotPrsnt WS43214321 ========================== {master:1} root@QFX-1> show virtual-chassis status Preprovisioned Virtual Chassis Virtual Chassis ID: 1234.1234.1234 Virtual Chassis Mode: Enabled Mstr Mixed Route Neighbor List Member ID Status Serial No Model prio Role Mode Mode ID Interface 0 (FPC 0) NotPrsnt WS12341234 1 (FPC 1) Prsnt WS43214321 qfx5110-48s-4c 129 Master* N VC
Since the LACP port are still up on both HW-1 and HW-2, is there any possibility of loop occur in this case and why?
Any idea or advice would be appreciated.
Regards,